The chemiluminescence based Ziplex® automated workstation focus array reproduces ovarian cancer Affymetrix GeneChip® expression profiles

Abstract

Background

As gene expression signatures may serve as biomarkers, there is a need to develop technologies based on mRNA expression patterns that are adaptable for translational research. Xceed Molecular has recently developed a Ziplex® technology, that can assay for gene expression of a discrete number of genes as a focused array. The present study has evaluated the reproducibility of the Ziplex system as applied to ovarian cancer research of genes shown to exhibit distinct expression profiles initially assessed by Affymetrix GeneChip® analyses.

Methods

The new chemiluminescence-based Ziplex® gene expression array technology was evaluated for the expression of 93 genes selected based on their Affymetrix GeneChip® profiles as applied to ovarian cancer research. Probe design was based on the Affymetrix target sequence that favors the 3' UTR of transcripts in order to maximize reproducibility across platforms. Gene expression analysis was performed using the Ziplex Automated Workstation. Statistical analyses were performed to evaluate reproducibility of both the magnitude of expression and differences between normal and tumor samples by correlation analyses, fold change differences and statistical significance testing.

Results

Expressions of 82 of 93 (88.2%) genes were highly correlated (p < 0.01) in a comparison of the two platforms. Overall, 75 of 93 (80.6%) genes exhibited consistent results in normal versus tumor tissue comparisons for both platforms (p < 0.001). The fold change differences were concordant for 87 of 93 (94%) genes, where there was agreement between the platforms regarding statistical significance for 71 (76%) of 87 genes. There was a strong agreement between the two platforms as shown by comparisons of log2 fold differences of gene expression between tumor versus normal samples (R = 0.93) and by Bland-Altman analysis, where greater than 90% of expression values fell within the 95% limits of agreement.

Conclusion

Overall concordance of gene expression patterns based on correlations, statistical significance between tumor and normal ovary data, and fold changes was consistent between the Ziplex and Affymetrix platforms. The reproducibility and ease-of-use of the technology suggests that the Ziplex array is a suitable platform for translational research.

Background

During the last decade, the advent of high-throughput techniques such as DNA microarrays, has allowed investigators to interrogate the expression level of thousands of genes concurrently. Due to the heterogeneous nature of many cancers in terms of both their genetic and molecular origins and their response to treatment, individualizing patient treatment based on the expression levels of signature genes may impact favorably on patient management [1, 2]. In ovarian cancer, discrete gene signatures have been determined from microarray analysis of ovarian cancer versus normal ovarian tissue [36], correlating gene expression profiles to survival or prognosis [7, 8], studies of chemotherapy resistance [9, 10], and functional studies such as chromosome transfer experiments [11, 12]. Recent studies have focused on a biomarker approach [13], with specific prognostic markers being discovered by relating gene expression profiles to clinical variables [1416]. In addition, there is a trend towards offering patient-tailored therapy, where expression profiles are related to key clinical features such as TP53 or HER2 status, surgical outcome and chemotherapy resistance [1, 17].

A major challenge in translating promising mRNA-based expression biomarkers has been the reproducibility of results when adapting gene expression assays to alternative platforms that are specifically developed for clinical laboratories. Xceed Molecular has recently developed a multiplex gene expression assay technology termed the Ziplex® Automated Workstation, designed to facilitate the expression analysis of a discrete number of genes (up to 120) specifically intended for clinical translational laboratories. The Ziplex array is essentially a three-dimensional array comprised of a microporous silicon matrix containing oligonucleotides probes mounted on a plastic tube. The probes are designed to overlap the target sequences of the probes used in large-scale gene expression array platforms from which the expression signature of interest was initially detected, such as the 3' UTR target sequences of the Affymetrix GeneChip®. However unlike most large-scale expression platforms, gene expression detection is by chemiluminescence. Recently, the Ziplex technology was compared to five other commercially available and well established gene expression profiling systems following the methods introduced by the MicroArray Quality Control (MAQC) consortium [1820] and reported in a white paper by Xceed Molecular [21]. The original MAQC study (MAQC Consortium, 2006) was undertaken because of concerns about the reproducibility and cross-platform concordance between gene expression profiling platforms, such as microarrays and alternative quantitative platforms. By assessing the expression levels of the MAQC panel of 53 genes on universal RNA samples, it was determined that the reproducibility, repeatability and sensitivity of the Ziplex system were at least equivalent to that of other MAQC platforms [21].

There is a need to implement reliable gene expression technologies that are readily adaptable to clinical laboratories in order to screen individual or multiple gene expression profiles ("signature") identified by large-scale gene expression assays of cancer samples. Our ovarian cancer research group (as well as other independent groups) has identified specific gene expression profiles from mining Affymetrix GeneChip expression data illustrating the utility of this approach at identifying gene signature patterns associated with specific parameters of the disease [14, 22]. Ovarian cancer specimens are typically large and exhibit less tumor heterogeneity and thus may be amenable to gene expression profiling in a reproducible way. However, until recently the gene expression technologies available that could easily be adapted to a clinical setting have been limited primarily by the expertise required to operate them. The recently developed Ziplex Automated Workstation offers a opportunity to develop RNA expression-based biomarkers that could readily be adapted to clinical settings as the 'all-in-one' technology appears to be relatively easy to use. However, this system has not been applied to ovarian cancer disease nor has its use been reported in human systems. In the present study we have evaluated the reproducibility of the Ziplex system using 93 genes, selected based on their expression profile as initially assessed by Affymetrix GeneChip microarray analyses from a number of ovarian cancer research studies from our group [6, 14, 2226]. These include genes which are highly differentially expressed between ovarian tumor samples and normal ovary samples that were identified using both newer and older generation GeneChips [6, 22, 25, 26]. In addition, to address the question of sensitivity, genes known to have a wide range of expression values were tested some of which show comparable values of expression between representative normal and ovarian tumor tissue samples but represent a broad range of expression values [25, 26]. Other genes known to be relevant to ovarian cancer including tumor suppressor genes and oncogenes were included in the analysis. Selected highly differentially expressed genes from an independent microarray analysis of ovarian tumors compared to short term cultures of normal epithelial cells was also included [3]. In many cases, the level of gene expression identified by Affymetrix GeneChip analysis was independently validated by semi-quantitative RT-PCR, real-time RT-PCR, or Northern Blot analysis [6, 14, 22, 2426]. Expression assays were performed using RNA from serous ovarian tumors, short term cultures of normal ovarian surface epithelial cells, and four well characterized ovarian cancer cell lines which were selected based on their known expression profiles using Affymetrix microarray analyses. Comparisons were made between the Ziplex system and expression profiles generated using the U133A Affymetrix GeneChip platform. An important aspect of this study was that gene expression profiling of Ziplex system was performed in a blinded fashion where the sample content was not known to the immediate users. It is envisaged that both the nature of the candidates chosen and their range of gene expression will permit for a direct comment on the sensitivity, reproducibility and overall utility of the Ziplex array as a platform for gene expression array analysis for translational research.

Methods

Source of RNA

Total RNA was extracted with TRIzol reagent (Gibco/BRL, Life Technologies Inc., Grand Island, NY) from primary cultures of normal ovarian surface epithelial (NOSE) cells, frozen malignant serous ovarian tumor (TOV) samples and epithelial ovarian cancer (EOC) cell lines as described previously [27]. Additional File 1 provides a description of samples used in the expression analyses.

The NOSE and TOV samples were attained from the study participants at the Centre de recherche du Centre hospitalier de l'Université de Montréal – Hôpital Hotel-Dieu and Institut du cancer de Montréal with signed informed consent as part of the tissue and clinical banking activities of the Banque de tissus et de données of the Réseau de recherche sur le cancer of the Fonds de la Recherche en Santé du Québec (FRSQ). The study was granted ethical approval from the Research Ethics Boards of the participating research institutes.

Ziplex array and probe design

The 93 genes used for assessing the reproducibility of the Ziplex array are shown in Table 1. The criteria for gene selection were: genes exhibiting statistically significant differential expression between NOSE and TOV samples as assessed by Affymetrix U133A microarray analysis; genes exhibiting a range of expression values (nominally low, medium or high) based on Affymetrix U133A microarray analysis, in order to assess sensitivity; genes exhibiting differential expression profiles based on older generation Affymetrix GeneChips (Hs 6000 [6] and Hu 6800 [23]); and genes known or suspected to play a role in ovarian cancer (Table 1). Initial selection criteria for genes in their original study included individual two-way comparisons [25, 26], fold-differences [6, 23], and fold change analysis using SAM (Significance Analysis of Microarrays) [3] between TOV and NOSE groups. Some genes were selected based on their low, mid or high range of expression values that did not necessarily exhibit statistically significant differences between TOV and NOSE groups.

Table 1 Selection Criteria of Genes Assayed by Ziplex Technology

The Ziplex array or TipChip is a three-dimensional array comprised of a microporous silicon matrix containing oligonucleotide probes that is mounted on a plastic tube. Each probe was spotted in triplicate. In order to replicate gene expression assays derived from the Affymetrix GeneChip analysis, probe set design was based on the Affymetrix U133A probe set target sequences for the selected gene (refer to Table 1). Gene names were assigned using UniGene ID Build 215 (17 August 2008). To improve accuracy of probe design, and to account for variation of probe hybridization, up to three probes were designed for each gene. From this exercise, a single probe was chosen to provide the most reliable and consistent quantification of gene expression. Gene accession numbers corresponding to the Affymetrix probe set sequences for each gene were verified by BLAST alignment searches of the NCBI Transcript Reference Sequences (RefSeq) database http://www.ncbi.nlm.nih.gov/projects/RefSeq/. Array Designer (Premier Biosoft, Palo Alto, CA) was used to generate three probes from each verified RefSeq transcript that were between 35 to 50 bases in length (median 46 base pairs), exhibited a melting temperature of approximately 70°C, represent a maximum distance of 1,500 base pairs from the from 3' end of the transcript, and exhibited minimal homology to non-target RefSeq sequences. Using this approach it was possible to design three probes for 92 of the 93 selected genes: APOE was represented by only two probes. For the 93 genes analyzed, the median distance from the 3' end was 263 bases, whereas less than 12% of the probes were more than 600 bases from the 3' end. Ten probes were also designed for genes that were not expected to vary significantly between TOV and NOSE samples based on approximately equal expression in the two sample types and relatively low coefficients of variation (18 to 20%) as assessed by Affymetrix U133A microarray analysis of the samples; such probes were potential normalization controls. Based on standard quality control measures of the manufacturer, three probes representing ACTB, GAPDH, and UBC and a set of standard control probes, including a set of 5' end biased probes for RPL4, POLR2A, ACTB, GAPDH and ACADVL were printed on each array for data normalization and quality assessment. The probes were printed on two separate TipChip arrays.

Hybridization and raw data collection

Total RNA from NOSE and TOV samples and the four EOC cell lines were prepared as described above and provided to Xceed Molecular for hybridization and data collection in a blinded manner. RNA quality (RNA integrity number (RIN)) using the Agilent 2100 Bioanalyzer Nano, total RNA assay was assessed for each sample (Additional File 1). For each sample, approximately 500 ng of RNA was amplified and labeled with the Illumina® TotalPrep™ RNA Amplification Kit (Ambion, Applied Biosystems Canada, Streetsville, ON, CANADA). Although sample MG0026 (TOV-1150G) had a low RIN number, it was carried through the study. Sample MG0001 (TOV-21G) had no detectable RIN number and MG0013 (NOV-1181) failed to produce amplified RNA. Neither of these samples were carried through the study. Five μg of the resulting biotin-labeled amplified RNA was hybridized on each TipChip. The target molecules were biotin labeled, and an HRP-streptavidin complex was used for imaging of bound targets by chemiluminescence. Hybridization, washing, chemiluminescent imaging and data collection were automatically performed by the Ziplex Workstation (Xceed Molecular, Toronto, ON, Canada).

Data normalization

The mean ratio of the intensities of the replicate probes that were printed on both of the ovarian cancer arrays were used to scale the data between the two TipChip arrays hybridized with each sample. The mean scaling factor for the 27 samples was 1.03 with a maximum of 1.23. The coefficients of variation (CV) across 27 samples and the expression differences between NOSE and TOV samples was calculated from the raw data for each of the 10 genes included on the arrays as potential normalization genes (Additional File 2). The geometric means of the signals for probes for PARK7, PI4KB, TBCB, and UBC with small CVs (mean of 25%) and insignificant differences between NOSE and TOV (p > 0.48) were used to normalize the data (refer to Additional File 2 for all normalization gene results). The data were analyzed with and without normalization.

Selection of optimal probe design

The hybridization intensities of the replicate probes designed for each gene for the 27 samples were compared to choose a single probe per gene with optimal performance. This assessment was based on signal intensity (well above the noise level and within the dynamic range of the system), minimum distance from the 3' end of the target sequence and correlation between different probe designs. Minimum distance from the 3' end is a consideration since the RNA sample preparation process is somewhat biased to the 3' end of the transcripts. The signals for probes for the same target should vary proportionally between different samples if both probes bind to and only to the nominal target. Good correlation between different Ziplex probe designs for genes in the RefSeq database, as well as good correlation with the Affymetrix data and discrimination between sample types, infers that probes bind to the intended target sequences. Data from the chosen probe was used for all subsequent analysis. Correlations of signal intensities for pairs of probes for the same genes are presented in Additional File 3.

Comparative analysis of Ziplex and Affymetrix data

Correlations between Ziplex and Affymetrix array datasets were calculated. The Affymetrix U133A data was previously derived from RNA expression analysis of the NOSE and TOV samples and EOC cell lines. Hybridization and scanning was performed at the McGill University and Genome Quebec Innovation Centre http://www.genomequebecplatforms.com. MAS5.0 software (Affymetrix® Microarray Suite) was used to quantify gene expression levels. Data was normalized by multiplying the raw value for an individual probe set (n = 22,216) by 100 and dividing by the mean of the raw expression values for the given sample data set, as described previously [23, 28]. Affymetrix and Ziplex data were matched by gene, and correlations (p < 0.01, using values only of greater than 4) and a graphical representation was determined using Mathematica (Version 6.03) software (Wolfram Research, Inc., Champaign, IL, USA). Mean signal intensity values were log2 transformed and compared between NOSE and TOV data using a Welch Rank Sum Test, for both Affymetrix microarray and Ziplex array data. A p-value of less than 0.001 was used as the significance level.

Composition of mean-difference plots followed the method of Bland and Altman [29]. Briefly, the mean of the log2 fold change and the difference between the log2 fold change for the platforms under comparison were calculated and plotted. The 95% limits of agreement were calculated as follows: log2 fold change difference ± 1.96 × standard deviation of the log2 fold change difference.

Quality control of Ziplex array data

The percent CVs were greater for probes with signals below 30. The overall median of the median probe percent CV was 4.7%. The median of the median percent CVs was 4.4% for probes with median intensities greater than 30, and 8.0% for probes with median CVs less than or equal to 30. The signal to noise (SNR) values is the average of the ratios for the net signals of the replicate spots to the standard deviation of the pixel values used to evaluate background levels (an image noise estimate). Average SNR ranged from -0.3 to 32.8. The signal intensities and ratios of intensity signals derived from 3' and 5' probes are shown in Additional File 4. Sample MG0001, which included many high 3'/5' ratios, was not included for subsequent analysis. The 3'/5' signal intensity ratios correlated with the RIN numbers and 28 S/18 S ratios (Additional File 5), indicating that, as expected, amplified RNA fragment lengths vary according to the integrity of the total RNA sample.

Results

Correlation of Affymetrix U133A and Ziplex array expression profiles

Normalized Affymetrix U133A and Ziplex gene expression data were matched by gene. For each gene expression platform, values less than 4 were considered to contribute to censoring bias and were not included in the correlation analysis. Correlations (log10 transformed) for paired gene expression data ranged from 0.0277 to 0.998, with an average correlation of 0.811 between Affymetrix and Ziplex gene expression data (Additional File 6). For a detailed summary of the correlation analysis, see also Additional File 7. The expression profiles of 82 of the 93 (88.2%) genes were significantly positively correlated (p < 0.01) in a comparison of the two platforms. As shown with the selected examples, genes exhibiting under-expression, such as ALDH1A3 and CCL2, or over-expression, such as APOE and EVI1, in the TOV samples relative to the NOSE samples by Affymetrix U133A microarray analysis also exhibited similar patterns of expression by Ziplex array (Figure 1). In contrast, TRAF4 expression was not correlated between the platforms (R2 = 0.0003). However, both platforms yielded low expression values for this gene. Although gene expression at very low levels may be difficult to assay and can be affected by technical variability, a good correspondence between platforms can be achieved with specific probes, as shown in the comparison of the BRCA1 expression profiles (R2 = 0.870) (Figure 1).

Figure 1
figure 1

Correlation plots of selected genes underexpressed in TOV (A, B), over-expressed in TOV (C, D) and showing low expression (E, F) across samples. Xceed Ziplex (XZP) expression data is plotted on the x axis and Affymetrix (AFX) microarray data on the y axis. The EOC cell lines are indicated in green (n = 3), TOV samples in red (n = 12) and NOSE samples in blue (n = 11). Correlation coefficients are shown at the bottom right.

Comparative analysis of fold changes of Affymetrix U133A and Ziplex array expression profiles

The fold change differences in gene expression were compared between the two platforms. There was a strong correspondence of gene expression patterns across the platforms when compared for each gene (Table 2). In terms of overall concordance of statistical significance between NOSE and TOV samples, there were consistent results for 75 of 93 genes by Affymetrix and Ziplex analysis (p < 0.001) by Welch rank sum test, in each platform. The fold change differences were concordant for 87 of 93 (94%) genes where there was agreement between the platforms regarding statistical significance for 71 (76%) of the 87 genes. The fold change differences were discordant for 6 genes, but the differences were statistically insignificant on both platforms for four of these genes. For example for the gene SERPIND1, there is no concordance in terms of fold change between the two platforms, but these fold change differences are not significant for either platform (p > 0.001). These results exemplifies that caution should be used when relying on fold change results alone. Notably, for two of the discordantly expressed genes (MSH6 and TFF1), the fold change differences were statistically significant (p < 0.001) only on the Ziplex platform but not for the Affymetrix platform.

Table 2 Comparison of mean signal intensity (SI) values for the 93 gene probes between NOSE and TOV samples

As shown in Figure 2A, there was a strong agreement between the two platforms as shown by comparisons of log2 fold differences of gene expression between TOV versus NOSE samples (R = 0.93) and by Bland-Altman analysis (Figure 2B), where the majority of probes exhibited expression profiles in comparative analyses that fell within the 95% limits of agreement. Both statistical methods of comparative analysis of log2 fold differences show minimal variance as the mean increases regardless of the direction of expression difference evaluated: genes selected based on over- or under-expression in TOV samples relative to NOSE samples. Although there were examples of expression differences which fell outside the 95% limits of agreement as observed in the Bland-Altman analysis such as for RGSF4, PDPN, IGKC, IGHG1, C1QTNF1, TFF1 and IL1B (Figure 2B), both the directionality and magnitude of TOV versus NOSE expression patterns were generally consistent (Figure 2A and Table 2).

Figure 2
figure 2

Comparison of the fold change difference in expression between NOSE and TOV samples for the Ziplex and Affymetrix platforms. A: The log2 fold change between the NOSE and TOV samples (mean NOSE signal intensity/mean TOV signal intensity) was calculated for the expression values of all 93 probes and plotted. Linear regression was performed resulting in the following model: log2 Affymetrix NOSE/TOV = 0.180098 + 1.0251794 log2 Ziplex NOSE/TOV with a Pearson's correlation coefficient (R) of 0.93. Probes that were not significant (p > 0.001 based on a Welch Rank Sum test) on either platform are indicated in grey, probes significant (p < 0.001 based on a Welch Rank Sum test) on both platforms are indicated in black, on only the Ziplex platform are indicated in blue and on only the Affymetrix platform in green. B: Bland-Altman plots for expression values of all probes. Values determined to be outliers are indicated in the mean-difference (of the log2 fold change values) plot. A difference in log2 fold change of 0 is indicated by a solid black line. The upper and lower 95% limits of agreement for the difference in log2 fold change are indicated by red dashed lines, and arrows on the right hand side. Expression values that fall outside of these lines are considered outliers and are identified by their gene name.

Discussion

The Ziplex array technology as applied to ovarian cancer research was capable of reproducing expression profiles of genes selected based on their Affymetrix GeneChip patterns. A high concordance of gene expression patterns was evident based on overall correlations, significance testing and fold-change comparisons derived from both platforms. The Ziplex array technology was validated by testing the expression of genes exhibiting not only significant differences in expression between normal tissues (NOSE) and ovarian cancer (TOV) samples but also the vast range in expression values exhibited by these samples using the Affymetrix microarray technology. Notable also is that comparisons were made between Affymetrix GeneChip data that was derived using MAS5 software rather than RMA analysis. We have routinely used MAS5 derived data in order to avoid potential skewing of low and high expression values which could occur with RMA treated data sets as this is more amenable to data sets of limited sample size [6, 23, 25, 26, 30]. MAS5 derived data also allows for exclusion of data that may represent ambiguous expression values as reflected in a reliability score based on comparison of hybridization to sets of probes representing matched and mismatch sequences complementary to the intended target RNA sequence. A recent study has re-evaluated the merits of using MAS5 data with detection call algorithms demonstrating its overall utility [31]. Our results are consistent with a previous study which had tested the analytical sensitivity, repeatability and differential expression of the Ziplex technology within a MAQC study framework [21]. As with all gene expression platforms, reproducibility is more variable within very low range of gene expression. Gene expression values in the low range across comparable groups would unlikely be developed as RNA expression biomarkers at the present time regardless of platform used. The MAQC study included a comparison of Xceed Molecular platform performance with at least three major gene expression platforms in current use in the research community, such as Affymetrix GeneChips, Agilent cDNA arrays, and real-time RT-PCR. The implementation of some of these various technology platforms in a clinical setting may require significant infrastructure which may be awkward to implement due to the level of expertise involved. In some cases, costs may also be prohibitive but this should diminish over time with increase in usage in clinical settings. It is also not clear that expression biomarkers are readily adaptable to all cancer types as this requires sufficient clinical specimens to extract amounts of good quality RNA for RNA biomarker screening to succeed. Tumor heterogeneity is also an issue. The large size and largely tumor cell composition of ovarian cancer specimens may render this disease more readily amenable to the development and implementation of RNA biomarker screening strategies in order to improve health care of ovarian cancer patients. The ease with which to use the Ziplex Automated Workstation focus array and the fact that it appears to perform overall as well as highly sensitive gene expression technologies including real-time RT-PCR, suggests that this new platform might be amenable to translational research of gene expression-based biomarkers for ovarian cancer initially identified from established large-scale gene expression platforms.

Data normalization of gene expression values is a subject of intense study and is a major consideration when moving from one technology platform to another [4, 5]. In this study, data normalization of the Ziplex data was achieved by using the expression values derived from seven genes, each of which had low CV values across all samples tested. Since the input quantity of amplified RNA was equivalent for all Ziplex arrays, raw data could also have been used in our analysis. A statistical analysis based on correlations and fold-changes found negligible differences between raw and normalized data (not shown). Affymetrix GeneChip and Ziplex systems also differ in a number of technical ways that may affect the determination of gene expression. Affymetrix probe design is based on 11 oligonucleotide probes, 25 base pairs in size, within a target sequence of several hundred base pairs. The gene expression value is based on the median of the measured signal from the 11 probes. The probe design for the Ziplex system is based on oligonucleotide probes ranging from 35 to 50 bases. In this study three probes were designed and tested for each target gene and a single optimal probe was chosen. The visualization system for gene expression differs for both platforms where expression using the Ziplex array is measured by chemiluminescence, whereas fluorescence is used for the Affymetrix GeneChip. In spite of these differences, our findings along with an independent assessment of the Ziplex system [21] indicated a high degree of correspondence in expression profiles generated across both platforms. The overall findings are not surprising given that the probe design was intentionally targeted to similar 3'UTR sequences for the tested gene. Thus, the overall reproducibility of expression profiles along with the possibility of using raw data would be an attractive feature of applying the Ziplex system to validated biomarkers that were discovered using the Affymetrix platform.

The expression patterns of many of the tested genes were previously validated by an independent technique from our research group. RT-PCR analyses of ovarian cancer samples validated gene expression profiles of TMEM158, GBE1 and HEG1 from a chromosome 3 transcriptome analysis [25] and IGFBP4, PTRF and C1QTNF1 from a chromosome 17 transcriptome analysis [26]. The Ziplex platform also revealed over-expression of genes (ZNF74, PIK4CA, SERPIND1, LZTR1 and CRKL) associated with a chromosome 22q11 amplicon found in the OV90 EOC cell line and initially characterized by earlier generation Affymetrix expression microarrays and validated by RT-PCR and Northern blot analysis [23]. Differential expression of SPARC, a tumor suppressor gene implicated in ovarian cancer, has been shown to give consistent expression profiles in EOC cell lines and samples across a number of Affymetrix GeneChip® platforms and by RT-PCR from our group and others [6, 30, 32]. This indicates the utility of using older generation Affymetrix GeneChip data where good concordance can be observed with historical data and the accuracy of the earlier generation GeneChips has been evaluated by alternative techniques in the literature [6, 23]. This is an important consideration particularly given the large number of historical data sets that are available for further mining of potential gene expression biomarkers. Northern blot analysis has validated expression of MYC, HSPD1, TP53 and PGAM1 which were initially found to be differentially expressed in our EOC cell lines by the prototype Affymetrix GeneChip [6]. Concordance of gene expression was also evident from the 10 genes (see Table 1) selected based on an Affymetrix U133A microarray analysis of TOV samples and short term cultures of NOSE samples reported by an independent group [3]. BTF4 is a potential prognostic marker for ovarian cancer and was originally identified by Affymetrix microarray technology and then validated by real-time RT-PCR analysis [14]. Assaying the expression of BTF4 in clinical specimens is of particular interest because at the time of study there was no available antibody, illustrating the need for a reliable and accurate quantitative gene expression platform for RNA molecular markers.

Conclusion

It is becoming increasingly apparent that expression signatures involving multiple genes can be correlated with various clinical parameters of disease, and in turn that these signatures could be used as biomarkers [4, 5]. Although the expression signatures are gleaned from the statistical analyses of transcriptomes from genome-wide expression analyses, such as with use of Affymetrix GeneChip, the use of such arrays requires technical expertise and infrastructure that is not at the present time readily adaptable to clinical laboratories. In this study we have shown the concordance of the expression signatures derived from Affymetrix microarray analysis by the Ziplex array technology, suggesting that it is amenable for translational research of expression signature biomarkers for ovarian cancer.

Abbreviations

RNA:

ribonucleic acid

mRNA:

messenger ribonucleic acid

UTR:

untranslated region

R:

correlation coefficient

MAQC:

MicroArray Quality Control

RT-PCR:

reverse transcription polymerase chain reaction

NOSE cells:

normal ovarian surface epithelial cells

TOV:

ovarian tumor

EOC:

epithelial ovarian cancer

BLAST:

Basic Local Alignment Search Tool

NCBI:

National Centre for Biotechnology Information

RIN:

RNA integrity number

HRP:

horseradish peroxidase

SNR:

signal to noise ratio

SI:

signal intensity.

References

  1. Agarwal R, Kaye SB: Expression profiling and individualisation of treatment for ovarian cancer. Curr Opin Pharmacol. 2006, 6: 345-349. 10.1016/j.coph.2006.02.007.

    Article  CAS  PubMed  Google Scholar 

  2. van't Veer LJ, Bernards R: Enabling personalized cancer medicine through analysis of gene-expression patterns. Nature. 2008, 452: 564-570. 10.1038/nature06915.

    Article  PubMed  Google Scholar 

  3. Bignotti E, Tassi RA, Calza S, Ravaggi A, Romani C, Rossi E, Falchetti M, Odicino FE, Pecorelli S, Santin AD: Differential gene expression profiles between tumor biopsies and short-term primary cultures of ovarian serous carcinomas: identification of novel molecular biomarkers for early diagnosis and therapy. Gynecol Oncol. 2006, 103: 405-416. 10.1016/j.ygyno.2006.03.056.

    Article  CAS  PubMed  Google Scholar 

  4. Konstantinopoulos PA, Spentzos D, Cannistra SA: Gene-expression profiling in epithelial ovarian cancer. Nat Clin Pract Oncol. 2008, 5: 577-587. 10.1038/ncponc1178.

    Article  CAS  PubMed  Google Scholar 

  5. Le Page C, Provencher D, Maugard CM, Ouellet V, Mes-Masson AM: Signature of a silent killer: expression profiling in epithelial ovarian cancer. Expert Rev Mol Diagn. 2004, 4: 157-167. 10.1586/14737159.4.2.157.

    Article  CAS  PubMed  Google Scholar 

  6. Tonin PN, Hudson TJ, Rodier F, Bossolasco M, Lee PD, Novak J, Manderson EN, Provencher D, Mes-Masson AM: Microarray analysis of gene expression mirrors the biology of an ovarian cancer model. Oncogene. 2001, 20: 6617-6626. 10.1038/sj.onc.1204804.

    Article  CAS  PubMed  Google Scholar 

  7. Bonome T, Levine DA, Shih J, Randonovich M, Pise-Masison CA, Bogomolniy F, Ozbun L, Brady J, Barrett JC, Boyd J, Birrer MJ: A gene signature predicting for survival in suboptimally debulked patients with ovarian cancer. Cancer Res. 2008, 68: 5478-5486. 10.1158/0008-5472.CAN-07-6595.

    Article  CAS  PubMed  Google Scholar 

  8. Spentzos D, Levine DA, Ramoni MF, Joseph M, Gu X, Boyd J, Libermann TA, Cannistra SA: Gene expression signature with independent prognostic significance in epithelial ovarian cancer. J Clin Oncol. 2004, 22: 4700-4710. 10.1200/JCO.2004.04.070.

    Article  PubMed  Google Scholar 

  9. Bernardini M, Lee CH, Beheshti B, Prasad M, Albert M, Marrano P, Begley H, Shaw P, Covens A, Murphy J, Rosen B, Minkin S, Squire JA, Macgregor PF: High-resolution mapping of genomic imbalance and identification of gene expression profiles associated with differential chemotherapy response in serous epithelial ovarian cancer. Neoplasia. 2005, 7: 603-613. 10.1593/neo.04760.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  10. Dressman HK, Berchuck A, Chan G, Zhai J, Bild A, Sayer R, Cragun J, Clarke J, Whitaker RS, Li L, Gray J, Marks J, Ginsburg GS, Potti A, West M, Nevins JR, Lancaster JM: An integrated genomic-based approach to individualized treatment of patients with advanced-stage ovarian cancer. J Clin Oncol. 2007, 25: 517-525. 10.1200/JCO.2006.06.3743.

    Article  CAS  PubMed  Google Scholar 

  11. Cody NA, Ouellet V, Manderson EN, Quinn MC, Filali-Mouhim A, Tellis P, Zietarska M, Provencher DM, Mes-Masson AM, Chevrette M, Tonin PN: Transfer of chromosome 3 fragments suppresses tumorigenicity of an ovarian cancer cell line monoallelic for chromosome 3p. Oncogene. 2007, 26: 618-632. 10.1038/sj.onc.1209821.

    Article  CAS  PubMed  Google Scholar 

  12. Stronach EA, Sellar GC, Blenkiron C, Rabiasz GJ, Taylor KJ, Miller EP, Massie CE, Al-Nafussi A, Smyth JF, Porteous DJ, Gabra H: Identification of clinically relevant genes on chromosome 11 in a functional model of ovarian cancer tumor suppression. Cancer Res. 2003, 63: 8648-8655.

    CAS  PubMed  Google Scholar 

  13. Coticchia CM, Yang J, Moses MA: Ovarian cancer biomarkers: current options and future promise. J Natl Compr Canc Netw. 2008, 6: 795-802.

    PubMed Central  CAS  PubMed  Google Scholar 

  14. Le Page C, Ouellet V, Quinn MC, Tonin PN, Provencher DM, Mes-Masson AM: BTF4/BTNA3.2 and GCS as candidate mRNA prognostic markers in epithelial ovarian cancer. Cancer Epidemiol Biomarkers Prev. 2008, 17: 913-920. 10.1158/1055-9965.EPI-07-0692.

    Article  CAS  PubMed  Google Scholar 

  15. Partheen K, Levan K, Osterberg L, Claesson I, Fallenius G, Sundfeldt K, Horvath G: Four potential biomarkers as prognostic factors in stage III serous ovarian adenocarcinomas. Int J Cancer. 2008, 123: 2130-2137. 10.1002/ijc.23758.

    Article  CAS  PubMed  Google Scholar 

  16. Tanner B, Hasenclever D, Stern K, Schormann W, Bezler M, Hermes M, Brulport M, Bauer A, Schiffer IB, Gebhard S, Schmidt M, Steiner E, Sehouli J, Edelmann J, Lauter J, Lessig R, Krishnamurthi K, Ullrich A, Hengstler JG: ErbB-3 predicts survival in ovarian cancer. J Clin Oncol. 2006, 24: 4317-4323. 10.1200/JCO.2005.04.8397.

    Article  CAS  PubMed  Google Scholar 

  17. Crijns AP, Duiker EW, de Jong S, Willemse PH, Zee van der AG, de Vries EG: Molecular prognostic markers in ovarian cancer: toward patient-tailored therapy. Int J Gynecol Cancer. 2006, 16 (Suppl 1): 152-165. 10.1111/j.1525-1438.2006.00503.x.

    Article  PubMed  Google Scholar 

  18. Chen JJ, Hsueh HM, Delongchamp RR, Lin CJ, Tsai CA: Reproducibility of microarray data: a further analysis of microarray quality control (MAQC) data. BMC Bioinformatics. 2007, 8: 412-10.1186/1471-2105-8-412.

    Article  PubMed Central  PubMed  Google Scholar 

  19. Patterson TA, Lobenhofer EK, Fulmer-Smentek SB, Collins PJ, Chu TM, Bao W, Fang H, Kawasaki ES, Hager J, Tikhonova IR, Walker SJ, Zhang L, Hurban P, de Longueville F, Fuscoe JC, Tong W, Shi L, Wolfinger RD: Performance comparison of one-color and two-color platforms within the MicroArray Quality Control (MAQC) project. Nat Biotechnol. 2006, 24: 1140-1150. 10.1038/nbt1242.

    Article  CAS  PubMed  Google Scholar 

  20. Shi L, Reid LH, Jones WD, Shippy R, Warrington JA, Baker SC, Collins PJ, de Longueville F, Kawasaki ES, Lee KY, Luo Y, Sun YA, Willey JC, Setterquist RA, Fischer GM, Tong W, Dragan YP, Dix DJ, Frueh FW, Goodsaid FM, Herman D, Jensen RV, Johnson CD, Lobenhofer EK, Puri RK, Schrf U, Thierry-Mieg J, Wang C, Wilson M, Wolber PK: The MicroArray Quality Control (MAQC) project shows inter- and intraplatform reproducibility of gene expression measurements. Nat Biotechnol. 2006, 24: 1151-1161. 10.1038/nbt1239.

    Article  CAS  PubMed  Google Scholar 

  21. Jones M, Dempsey A, Englert D: Comparison of the Ziplex Performance to Expression Platforms Using the MAQC study protocol. Xceed Molecular WhitePaper. 2007, [http://www.xceedmolecular.com/MAQC%20Whitepaper%20v1.pdf]

    Google Scholar 

  22. Le Page C, Ouellet V, Madore J, Hudson TJ, Tonin PN, Provencher DM, Mes-Masson AM: From gene profiling to diagnostic markers: IL-18 and FGF-2 complement CA125 as serum-based markers in epithelial ovarian cancer. Int J Cancer. 2006, 118: 1750-1758. 10.1002/ijc.21521.

    Article  CAS  PubMed  Google Scholar 

  23. Arcand SL, Mes-Masson AM, Provencher D, Hudson TJ, Tonin PN: Gene expression microarray analysis and genome databases facilitate the characterization of a chromosome 22 derived homogeneously staining region. Mol Carcinog. 2004, 41: 17-38. 10.1002/mc.20038.

    Article  CAS  PubMed  Google Scholar 

  24. Benoit MH, Hudson TJ, Maire G, Squire JA, Arcand SL, Provencher D, Mes-Masson AM, Tonin PN: Global analysis of chromosome X gene expression in primary cultures of normal ovarian surface epithelial cells and epithelial ovarian cancer cell lines. Int J Oncol. 2007, 30: 5-17.

    PubMed  Google Scholar 

  25. Birch AH, Quinn MC, Filali-Mouhim A, Provencher DM, Mes-Masson AM, Tonin PN: Transcriptome analysis of serous ovarian cancers identifies differentially expressed chromosome 3 genes. Mol Carcinog. 2008, 47: 56-65. 10.1002/mc.20361.

    Article  CAS  PubMed  Google Scholar 

  26. Wojnarowicz PM, Breznan A, Arcand SL, Filali-Mouhim A, Provencher DM, Mes-Masson AM, Tonin PN: Construction of a chromosome 17 transcriptome in serous ovarian cancer identifies differentially expressed genes. Int J Gynecol Cancer. 2008, 18: 963-975. 10.1111/j.1525-1438.2007.01134.x.

    Article  CAS  PubMed  Google Scholar 

  27. Presneau N, Mes-Masson AM, Ge B, Provencher D, Hudson TJ, Tonin PN: Patterns of expression of chromosome 17 genes in primary cultures of normal ovarian surface epithelia and epithelial ovarian cancer cell lines. Oncogene. 2003, 22: 1568-1579. 10.1038/sj.onc.1206219.

    Article  CAS  PubMed  Google Scholar 

  28. Novak JP, Sladek R, Hudson TJ: Characterization of variability in large-scale gene expression data: implications for study design. Genomics. 2002, 79: 104-113. 10.1006/geno.2001.6675.

    Article  CAS  PubMed  Google Scholar 

  29. Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1: 307-310.

    Article  CAS  PubMed  Google Scholar 

  30. Quinn MC, Filali-Mouhim A, Provencher DM, Mes-Masson AM, Tonin PN: Reprogramming of the transcriptome in a novel chromosome 3 transfer tumor suppressor ovarian cancer cell line model affected molecular networks that are characteristic of ovarian cancer. Mol Carcinog. 2009, 48: 648-661. 10.1002/mc.20511.

    Article  CAS  PubMed  Google Scholar 

  31. Pepper SD, Saunders EK, Edwards LE, Wilson CL, Miller CJ: The utility of MAS5 expression summary and detection call algorithms. BMC Bioinformatics. 2007, 8: 273-10.1186/1471-2105-8-273.

    Article  PubMed Central  PubMed  Google Scholar 

  32. Biade S, Marinucci M, Schick J, Roberts D, Workman G, Sage EH, O'Dwyer PJ, Livolsi VA, Johnson SW: Gene expression profiling of human ovarian tumours. Br J Cancer. 2006, 95: 1092-1100. 10.1038/sj.bjc.6603346.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

Manon Deladurantaye provided technical assistance with sample preparation. PT is an Associate Professor and Medical Scientist at The Research Institute of the McGill University Health Centre which receives support from the Fonds de la Recherche en Santé du Québec (FRSQ). AB is a recipient of a graduate scholarship from the Department of Medicine and the Research Institute of the McGill University Health Centre and PW is a recipient of a Canadian Institutes of Health Research doctoral research award. The ovarian tumor banking was supported by the Banque de tissus et de données of the Réseau de recherche sur le cancer of the FRSQ affiliated with the Canadian Tumour Respository Network (CRTNet). This work was supported by grants from the Genome Canada/Génome Québec, the Canadian Institutes of Health Research and joint funding from The Terry Fox Research Institute and Canadian Partnership Against Cancer Corporation (Project: 2008-03T) to PT, AMMM and DP.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Patricia N Tonin.

Additional information

Competing interests

DW, FY, AD and DE are employees of Xceed Molecular.

Authors' contributions

MQ contributed to candidate gene selection for the study, sample selection, performed data analysis (correlations), results interpretation and wrote the majority of the paper. AMMM, DP, SA, AB and PW aiding in selecting candidate genes, preliminary results analysis and review of the paper draft. DW and FY performed sample quality control, RNA amplification and hybridization at Xceed Molecular. AD performed statistical analysis and aided with the writing of the draft. DE designed Ziplex probes, performed preliminary data analysis and contributed to the writing of the draft. PT and DE conceptualized the project, and aided in writing the initial draft. PT was the project leader. All authors read and approved the final manuscript.

Electronic supplementary material

Additional file 1: Sample description. RNA samples used in the expression analyses. (XLS 32 KB)

12967_2009_366_MOESM2_ESM.xls

Additional file 2: Genes for normalization. Differential expression between NOSE and TOV in the raw data (log2 ratios, and T-test). (XLS 34 KB)

12967_2009_366_MOESM3_ESM.pdf

Additional file 3: Correlations between different probe designs for the same target gene. Three different probes were designed and tested for each of the target genes, except for one of the genes (APOE) for which there were two designs. Each row of plots contains correlations between probes for a given gene. The accession numbers and gene symbols are indicated on the plots. Plots with linear scales are shown on the left, and plots with log10scales are shown on the right. The probes are identified in the axis labels with an Xceed part number and the gene symbol. The distance of each probe from the 3' end of the sequence corresponding to the accession number is shown after the colon in the axis labels. The colors used to plot the data for each sample are: NOSE samples – blue, TOV samples – red, cell line samples – green. Low intensity probes are plotted with open symbols. (PDF 2 MB)

12967_2009_366_MOESM4_ESM.xls

Additional file 4: Signal intensities and 3'/5' ratios for all ten 5' control probes on duplicate chips. 3', 5' signial intensities and 3'/5' ratios for each sample, for the genes RPL4, POL2RA, ACTB, GAPD and ACADVL2. (XLS 28 KB)

12967_2009_366_MOESM5_ESM.ppt

Additional file 5: RNA quality control. Correlation between the geometric mean of seven 3'/5' control probe ratios and RIN number or 28 S/18 S ratios. Samples MG0001 (TOV-21G) and MG0026 (NOSE-1181) are not included. (PPT 292 KB)

12967_2009_366_MOESM6_ESM.ppt

Additional file 6: Correlations between Affymetrix U133A and Xceed Ziplex data. Correlation graphs plotted for all 93 study genes, organized alphabetically. TOV samples are shaded red, NOSE blue and cell lines are indicated in green. (PPT 780 KB)

12967_2009_366_MOESM7_ESM.xls

Additional file 7: Correlation analysis of Ziplex versus Affymetrix gene expression data. Correlation analysis for all genes including p-value and R-squared. (XLS 40 KB)

Authors’ original submitted files for images

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Quinn, M.C., Wilson, D.J., Young, F. et al. The chemiluminescence based Ziplex® automated workstation focus array reproduces ovarian cancer Affymetrix GeneChip® expression profiles. J Transl Med 7, 55 (2009). https://doi.org/10.1186/1479-5876-7-55

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1479-5876-7-55

Keywords